Brochure
Skylight Guardrail Brochure
A free-standing skylight guardrail that sits on the roof without piercing the membrane. Modular to any size, galvanized, and independently tested to the OSHA standard.
What’s inside
- Why a skylight is treated as a hole in the roof, and why people fall through them
- A free-standing guardrail that sits on the roof and does not pierce the membrane
- A modular kit that expands to fit domed, pyramid and barrel skylights of any size
- System specs: 42-inch rail height, 200 lb load, 3° max pitch, and no roof penetrations
- Related solutions: skylight covers and roof hatch guardrail
- What OSHA requires around a skylight: 4 feet in general industry, 6 feet in construction
A skylight can look like solid roof, but it is a hole
Dirt, snow, or debris can hide a skylight. A worker in the middle of the roof may not see the risk until it is too late. More people fall through skylights than over the edge of the roof.
Passive protection that does not pierce the roof
Tritech Skylight Guardrail is a free-standing system. It sits on the roof on recycled PVC bases, so the membrane is not damaged. It does not rely on a harness or special training to work. Standard parts expand to fit skylights of any size, including domed, pyramid, and barrel shapes. The galvanized rail is independently tested to the OSHA standard.
Key specs
| Top rail height | 42 in ± 3 in |
|---|---|
| Outward or downward force | 200 lb |
| Max roof pitch | 3° |
| Roof penetrations | None; free-standing |
| Material | Rigid galvanized pipe |
| Bases | Recycled PVC with clamping rings |
Standards referenced
- OSHA 29 CFR 1910.28(b)(3)
- OSHA 29 CFR 1910.29(b)
- OSHA 29 CFR 1926.501
Questions about this brochure
What does OSHA require around a skylight?
In general industry, a worker who could fall 4 feet or more through a skylight must be protected by a guardrail, a screen, a cover, or a personal fall arrest system (29 CFR 1910.28(b)(3)). In construction, the trigger is 6 feet (1926.501).
Does the guardrail have to be bolted to the roof?
No. It is free-standing. Recycled PVC bases sit on the roof, so the membrane is not pierced.
What size skylight will it fit?
It is modular. Standard parts expand to fit domed, pyramid and barrel skylights of any size.
Will it block daylight?
No. The rail stands around the skylight and does not cover the opening.
Installed, not just specified
On site with Tritech
Since 1993 turnkey fall protection
Have a site in mind?
Tell us about the hazard. We’ll tell you what we’d install, how long it takes and what it costs.