Brochure

Rooftop Guardrail Systems Brochure

How Tritech engineers rooftop guardrail for membrane, metal, parapet and temporary roofs: four configurations, edge-distance zones and site engineering.

PDF · 4 pages · 2.2 MB · Rev. 2026

Download the PDF Work email required, once

What’s inside

  • Three work zones defined by distance from the roof edge, and what each allows
  • Freestanding counterbalanced guardrail for membrane, built-up and concrete roofs
  • Standing-seam guardrail for metal roofs up to a 45° pitch
  • Parapet and wall-mounted rail with no counterweights on the roof
  • Portable guardrail for contractors and short-term projects
  • The wind, layout and anchor calculations delivered with every run

The edge is where the exposure is, and equipment tends to sit near it

Roof trips are mostly to service equipment, and it is often installed near the edge. This brochure is for facility managers, safety leads and building owners. It walks through OSHA 29 CFR 1910.28(b)(13) for low-slope roofs, which sets the controls allowed inside 6 ft of the edge, between 6 and 15 ft, and beyond 15 ft, including when a designated area with a physical warning line can be used and when it cannot.

Guardrail is the one control that asks nothing of the worker

Harnesses must be worn and anchored and designated areas enforced; a guardrail just stays in place. The brochure covers four Tritech configurations built from one modular, galvanized component system:

  • Freestanding counterbalanced guardrail that sits on the membrane with no penetrations
  • Metal roof guardrail clamped to the standing seam or profile
  • Parapet and wall-mounted rail for tight roofs
  • Portable guardrail that moves with the work

It also shows how a modular run is routed around pipes, ductwork, curbs and HVAC units without leaving a gap.

A counterbalanced guardrail is a structure and is engineered as one

Each base acts as a lever through the cantilever arm, so arm length, base count and spacing decide whether the rail holds the 200 lb test load required by 1910.29(b) and stays put in wind. Tritech engineers size every run for the building: wind load by basic wind velocity, exposure category and roof height; layout drawings for post spacing, arms, corners and obstructions; and compliance documentation against 1910.28 and 1910.29 with third-party test data. Tritech has done this work across North America since 1993.

Key specs

Top-rail height42 in. (±3 in.)
Top-rail load200 lb at any point, outward or downward
Counterbalance base weight30 lb, molded from 100% recycled PVC
Roof penetrations0 (no drilling, welding or hot work)
Counterbalance arm lengths91½ in. full-length, 55 in. compact
Metal roof pitchUp to 45°
Parapet post spacing8 ft centers
Warning line height (designated areas)34 to 39 in.
FinishHot-dip galvanized; powder-coated RAL colors available

Standards referenced

  • OSHA 29 CFR 1910.28(b)(13)
  • OSHA 29 CFR 1910.29(b)
  • OSHA 29 CFR 1910.28
  • OSHA 29 CFR 1910.29

Questions about this brochure

What does OSHA require for workers near the edge of a low-slope roof?

Under 29 CFR 1910.28(b)(13), work inside 6 ft of the edge needs guardrail, safety net, travel restraint or personal fall arrest; no designated area is allowed. Between 6 and 15 ft, a designated area is allowed only if the work is both infrequent and temporary. At 15 ft or more, a designated area is an option, but the exposure must still be controlled.

How does OSHA define infrequent and temporary roof access?

Infrequent means occasional or sporadic, usually in response to a breakdown rather than routine service. Federal OSHA has cited access more than once a month as frequent, and many safety professionals use once a quarter or less. Temporary means a short task of an hour or two, done in one trip with the tools in hand, with no diagnostic work.

Can a painted line serve as an OSHA designated area?

No. OSHA does not accept painted lines. A designated area needs a physical warning line between the worker and the edge, set 34 to 39 in. high, so it stays visible under snow, dust, debris or equipment. Where roof work is not both infrequent and temporary, a designated area is not permitted and guardrail is the practical answer.

Does the Tritech Rooftop Guardrail meet OSHA guardrail criteria?

Yes. Tritech rooftop guardrail is engineered to the OSHA 29 CFR 1910.29(b) criteria: a top rail at 42 in. (±3 in.) that withstands a 200 lb force applied at any point along it. On a freestanding run, the counterbalanced bases and cantilever arms carry that load with no fasteners in the roof. Tritech provides the engineering and compliance documentation for each layout.

Installed, not just specified

On site with Tritech

1,800+ successful installations in the USA

  • Yellow overhead rigid rail and guardrail along a conveyor catwalk inside a distribution facility
  • Aerial view of a long access platform with yellow guardrail beside the tracks in an intermodal rail yard
  • Galvanized guardrail and a self-closing gate around a roof hatch with a grated walkway on a metal roof
  • Yellow counterweighted guardrail along a large flat roof

More in the project gallery →

Downloads

All downloads →

Have a site in mind?

Tell us about the hazard. We’ll tell you what we’d install, how long it takes and what it costs.

Speak with an Expert

Brochure

Rooftop Guardrail Systems Brochure

Enter your work email and the PDF downloads straight away. We’ll email you the link too. You’ll only be asked once.